SpectraQC

Method

Test signal tone level

Line-up tone level conformance


What we measure and how

Measures the RMS audio level over the colour-bars region (ffmpeg volumedetect mean_volume on the trimmed audio) and compares it to the required line-up tone alignment level (test_signal.tone.level_dbfs, commonly -18 dBFS EBU or -20 dBFS SMPTE) within test_signal.tone.level_tolerance_db. Frequency and channel-routing verification are a follow-up (SQC-1131).


Provenance

Standards
EBU R68 (-18 dBFS alignment) · SMPTE RP 155 (-20 dBFS)

Spec fields consulted

These Universal Media Delivery Profile paths resolve this check's thresholds against your spec snapshot at the moment the job was submitted.

The full UMDP schema: /umdp.


Method identifier: test_signal_tone_level